Burndy BGBS Aluminum Lay-in Lug BGBS-5

Burndy BGBS-5 Aluminum Lay-in Lug

Please Call for Availability and Pricing
1-888-356-1662
Submit RFQ Form

    RFQ Form




    Description

    Burndey BGBS5 lay-in lugs are made of high strength aluminum alloy, these items can be used with copper or aluminum conductors. The connectors are for use with solar modules with a maximum thickness of 1/4 inches. Both are electro-tin plated and provided with stainless steel hardware.

    The serrations establish better contact and cut through oxidation, ensuring low contact resistance and high conductivity. The anodization on aluminum rails is non-conductive and electrical current cannot pass through this layer; the cup point screw penetrates this layer allowing current to flow into the aluminum connector and consequently, current flows to the conductor.

    Features and Benefits:
    Made of high strength aluminum alloy
    Electro-Tin plated
    Stainless steel hardware
    Cup point screw that penetrates anodization
    Lay-in feature
    Conductor size – Copper: 14 AWG – 6 AWG STR./SOL.
    Conductor Size – Aluminum: 12 AWG – 6 AWG STR./SOL.
    Serrations in conductor wire way cuts through oxidation
    For applications with 1/4 inch thick solar panels and other flat steel structures
    UL467 Listed for Grounding and Bonding
    UL2703 Listed

    Product Information

    Part Number

    BGBS-5

    Positive Connector (#8 AWG)
    AWG
    Positive Connector (#10 AWG)
    Overvoltage category/Pollution degree
    Pairs
    Part Number (female)
    Part Number (male)
    Part Numbers
    Rated impulse voltage
    Temperature
    Overall Length
    Power Dissipation
    Protection class
    Protection degree
    Put-Up Length
    Range of Cable Gland
    Rate Current
    Rated current
    Pollution Degree
    Overlap
    Orientation
    NEC
    Mounting Hardware:
    Negative Connector (#10 AWG)
    Max Bundle Diameter
    Max Cable Tie Width
    Max Wire Diameter
    Max. Interrupting Rating
    Maximum Support Interval
    Maximum wire size
    Outside Diameter
    Regulatory Approvals (600V/1000V)
    Negative Connector (#8 AWG)
    Outer Color
    Nominal OD
    Nominal Size
    Number of Wires
    Ohms
    Operating Temperature
    Operating Temperature Range
    Order Number
    Rated voltage
    Amperage Rating
    UV rating
    Voltage rating
    Type
    Type of Connector / Socket
    Type of termination
    Typical Contract Resistance
    UL
    UL Listing
    Voltage
    Wire Size Range
    Wall Thickness
    Test voltage
    Warranty
    Weight per Foot
    Width
    Wiley Catalog Number
    Wire Color
    Wire Diameter
    AWG Size
    Wire Type
    Standard
    SCCR Rating
    SCCR Rating 20
    Staubli / Multi-Contact Type
    Safety Class
    Shield 1 type
    Shield 2 type
    Size of Cables
    Special Feature:
    Standards
    Staubli / Multi-Contact Order #
    Time Constant
    Stranding
    Terminal Block
    Strap Length
    System voltage Max.
    TUV
    TV Rheinland
    Technical Drawing
    Terminal Block Internal Bus
    Guage
    Temperature range
    Materials
    Contact material
    Material:
    Contact resistance
    Color
    Color (Select Color)
    Conductor type
    Conductors
    Connector Type (#10 AWG)
    Drill Out
    Connector Type (#8 AWG)
    Cross-section
    Certifications
    Current Withstand Rating
    DC Voltage Ratings
    Degree of protection:
    Degree of protection mated
    Diameter
    Din Rai
    Material Dimensions
    Catalog Numbe
    Length / Width / Height (In.)
    Clamping range in mm
    Manufacturer
    Article Designation
    Acceptable Conduit Sizes
    Ace Configuration
    Ambient temperature range
    Amp Rating
    Ampacity
    Application degree
    Approvals
    Electrical Connections
    Article Number
    Certificate No.
    Assembled:
    Brochure
    CSA
    Cable Diameter
    Cap and Tray Quantity (8 Ft Lengths)
    Certification
    Capacitance
    Catalog Number:
    Temperature Rating
    Insulation
    Equipment Ground Conductor Diameter Range
    Equipment Ground Conductor Type
    Interrupting Rating
    IP Rating
    Inner Colors
    Input Wire Diameter Range
    Installation
    Insulation Resistance
    Flammability Rating
    Listing
    Internal Wiring
    Item Number:
    Fire Resistance
    Jacket type
    LAAP Article Number
    LAPP Article Number
    Length / Width / Height:
    Insulation material
    Environmental
    Local Order Number
    Hole Size In. [mm]:
    Heyco Part Numbers
    Heyco Part Number
    Hardware
    First Solar Series 6 Datasheet
    Flame class
    Flame retardant grade
    Flammability Class
    Flammability Classification
    Frame Thickness
    Locking system(UL)
    Fuse Amp Rating
    Fuse Ampere Rating
    Fuse Combiner Bus
    Fuse Holder
    Fuse Type
    Global Part Name
    Grounding
    Grounding Terminal
    Conductor size

    Copper: 14 AWG – 6 AWG STR./SOL. Aluminum: 12 AWG – 6 AWG STR./SOL.

    Technical Documents

    Spec Sheet Download
    Installation Manual Download